Alpine Tower Microwave Install
Alpine Tower Microwave Antenna Installation
Two 6-foot microwave systems integrated into an existing 400-foot communications tower

Installed 6-foot microwave antenna, tower-mounted radio, custom mount and ice shield at the Alpine Tower.
| LOCATION Alpine, New Jersey | CUSTOMER New York Power Authority / TRC | PROJECT TYPE Microwave infrastructure | COMPLETION April 2023 |
Project Overview
K2 Communications was engaged by New York Power Authority / TRC to support the installation of two new 6-foot microwave antenna systems on the 400-foot self-supporting Alpine Tower in Alpine, New Jersey. The project combined structural engineering, custom mount design, permitting, tower installation, RF cabling, grounding, electrical work, ice protection and final path alignment into a coordinated field effort.
PRIMARY K2 SERVICES
■ Antenna & wireless infrastructure
■ Engineering, permitting & structural coordination
■ Custom tower mounts
■ RF cabling & grounding
■ Electrical coordination
■ Microwave path alignment
The Challenge
NYPA required two new point-to-point microwave paths to be added to an existing, heavily developed communications tower. Each new 6-foot dish required a purpose-designed leg mount, tower-mounted outdoor radio equipment, transmission lines, grounding and ice protection at a high-elevation location.
| INSTALLATION | 300-FOOT LOCATION | 355-FOOT LOCATION |
| Tower leg | North leg | East leg |
| Antenna | Commscope USX6-6GR, 6 ft | Commscope USX6-6GR, 6 ft |
| Azimuth | 56.632° | 175.912° |
| Path length | 9.569 miles | 11.87 miles |
| Feedlines | Two CNT-400 runs | Two CNT-400 runs |
| Protection | Ice shield above dish | Ice shield above dish |
Engineering and Mount Design
Before construction, K2 coordinated a structural analysis of the existing tower using the proposed dishes, ODUs, feedlines and ice shields as the final loading condition. The analysis determined that the tower would meet TIA-222-H and the 2018 New Jersey Building Code with the new NYPA equipment installed, allowing the project to proceed without major structural reinforcement.
Custom mounts were engineered separately for the 300-foot and 355-foot locations, including tower clamps, mounting pipes, tie-back members and hot-dip-galvanized structural steel components. The 355-foot arrangement was revised to suit the final field configuration.

Engineering drawing showing the two dish elevations and custom mount configurations at 300 ft and 355 ft.
The K2 Solution
Tower installation — K2 coordinated and supervised installation of the two 6-foot microwave antennas, their tower-mounted ODUs/radios, custom mounts and ice shields at approximately 300 and 355 feet.
RF cabling and grounding — Two CNT-400 runs were installed to each antenna using the tower cable-support system. The design included coaxial surge protection and grounding kits at the top, midpoint and base of the tower runs.
Electrical infrastructure — A dedicated 240-volt, 20-amp circuit and submetering were provided for the microwave equipment.
Microwave alignment — The antennas served separate paths, so alignment work was performed on separate days to coordinate with the corresponding remote sites and establish the required links.
Permitting and closeout — K2 coordinated structural documentation, permit drawings, construction supervision and municipal inspection. Building and electrical approvals were completed in April 2023.
The Result
The completed project added two microwave communications paths to the Alpine Tower while making use of the existing structure and site infrastructure. K2 provided the engineering coordination, custom mounting solution, field installation, RF cabling, grounding, electrical coordination, ice protection and antenna alignment needed to bring the systems into service.
| DELIVERED SYSTEM ■ Two 6-foot microwave antennas at approximately 300 ft and 355 ft ■ Tower-mounted microwave ODUs/radios and custom leg mounts ■ Four CNT-400 transmission-line runs with grounding and surge protection ■ Two antenna ice shields ■ Dedicated electrical service and submetering ■ Final microwave path alignment |
Project Significance
| This project demonstrates K2 Communications’ ability to manage a microwave infrastructure project from engineering through final installation. By combining structural analysis, custom mount engineering, permitting, tower construction, RF cabling, electrical coordination and precision antenna alignment under a single project-management effort, K2 integrated two substantial microwave systems onto an existing 400-foot communications tower without the need for major tower reinforcement. |
Project documentation: K2 Communications quotations and project drawings; Towerkraft Engineering structural certification and mount drawings; municipal inspection records.